Solar charging an EV from a partially shaded roof

Trees shade the roof around part of the day. The owner models 25% PV loss, four peak sun hours, and 420 W panels for a 36-mile daily EV schedule.

Try a lower shade loss for a second roof face and compare the module count.

Inputs

Unit system

Results

Solar panels
8
Installed array
3.36 kW DC
Panel footprint
168 ft²
EV demand and solar generation
Daily solar and EV energyThe array produces an estimated 10.08 kWh daily against 10 kWh of charging demand.Daily energy (kWh)EV wall demand10 kWhSolar AC output10.08 kWh8 × 420 W modules3.36 kW DC
Daily driving
36 mi
Annual driving
13,140 mi
Daily EV wall demand
10 kWh
Daily solar AC output
10.08 kWh
Array target before rounding
3.33 kW DC
Installed cost after incentive
$9,408
Annual energy savings
$558.45
Simple solar payback
16.85 yr

Calculation notes

Daily battery demand equals miles divided by battery driving efficiency. Divide by charging efficiency to get wall energy.

Each installed kW produces peak sun hours × inverter efficiency × retained array output per day. Divide wall demand by that yield and round up to whole panels.

Simple payback uses the share of EV demand you expect to offset at the retail electricity price. Estimates use average daily generation and panel footprint. Use location-specific solar modeling, a roof layout, and the utility export tariff for a project quote.

Frequently asked questions

How much output does 25% shading leave in this roof scenario?

The worksheet uses 75% of the unshaded output. Four sun hours become three effective full-power hours before any other losses.

Why does this partially shaded design use eight modules?

The target is about 3.33 kW. Seven 420 W modules provide only 2.94 kW, while eight provide 3.36 kW.