Two EVs sharing a 100 amp home panel
A household has an estimated 65 A of existing design load on a 100 A panel. Two 32 A ports share the remaining conservative budget for an eight-hour night.
Change the existing load to compare the effect of a new appliance or an updated load calculation.
Results
- Overnight energy per EV
- 24.2 kWh
- Power per active EV
- 3.36 kW
- Active ports at once
- 2 / 2
- Power per EV when all run
- 3.36 kW
- Overnight range per EV
- 75 mi
- Screened continuous EV budget
- 28 A
- Applied total charging current
- 28 A
- Headroom at configured limit
- -5 A
- Headroom with applied load
- 0 A
- Headroom if all ports use maximum
- -45 A
The configured EV limit exceeds the screened headroom. Results apply the lower service budget.
Worksheet inputs
- Service or panel rating
- 100 A
- Existing non-EV design load
- 65 A
- Connected EVs or EVSE ports
- 2
- Maximum charging current per port
- 32 A
- Configured site charging limit
- 32 A
- Single-phase line-to-line voltage
- 240 V
- Overnight dwell time
- 8 h
- Wall-to-battery efficiency
- 90 %
- Fleet driving efficiency
- 3.1 mi/kWh
Calculation notes
Subtract the existing non-EV design load from the service rating and divide by 1.25 to screen the new continuous EV charging budget. The applied site limit is also capped by the controller setting and connected port ratings.
If each port can receive at least the assumed 6 A minimum, all vehicles share the current at once. Otherwise, the calculator estimates rotating groups of active ports with equal dwell time over the night.
This is a conservative single-phase planning check. Use a qualified designer for the adopted load calculation, listed energy-management equipment, branch circuits, and phase balancing.
Frequently asked questions
What does each EV get while both charge on the 100 A panel example?
The 35 A design headroom screens at 28 A of continuous EV charging. Each connected car gets 14 A.
How much energy does each car receive over eight hours?
At 240 V, 14 A is 3.36 kW. Eight hours at 90% charging efficiency puts about 24.2 kWh into each battery.